Kitchen Ventilation: Range Hood Sizing and Picks (2026)
For a standard 30-inch range with a duct to the outside, buy the Broan Glacier GLA1303SS. Its low setting is HVI-certified at 130 CFM and 1.5 sones, above ASHRAE 62.2’s 100 CFM minimum and under its 3-sone limit, and high reaches 240 CFM. Heavy cooking on gas calls for the Broan Mantra MTR3304SS.
Our Top Picks at a Glance
Compare the Range Hoods
| Model (30 in) | Venting | HVI airflow, low to high | HVI sones, low to high | Speeds | Filters | ENERGY STAR | Price | Link |
|---|---|---|---|---|---|---|---|---|
| Broan-NuTone GLA1303SS | Ducted, convertible | 130 to 240 CFM | 1.5 to 6.5 | 2 | Micro mesh, dishwasher-safe | Yes | ~$224 | GLA1303SS on Amazon (~$224) |
| Broan-NuTone GLA2303SS | Ducted, convertible | 130 to 240 CFM | 1.5 to 6.5 | 3 | Micro mesh, dishwasher-safe | Yes | ~$299 | GLA2303SS on Amazon (~$299) |
| Broan-NuTone MTR3304SS | Ducted, convertible | 160 to 390 CFM | 1.3 to 7.5 | 3, plus heat-sensing auto | Hybrid baffle, dishwasher-safe | Yes | ~$499 | MTR3304SS on Amazon (~$499) |
| Broan-NuTone F403004 | Ducted, convertible | 110 to 160 CFM | 4.0 to 7.5 | 2 | Aluminum mesh, dishwasher-safe | No | ~$138 | F403004 on Amazon (~$138) |
| Broan-NuTone 413004 | Non-ducted only | Not published | 3.5 (not HVI-certified) | 2 | Grease and charcoal, replace every 6 months | No | ~$109 | 413004 on Amazon (~$109) |
Airflow and sones are Broan’s HVI-certified figures at 0.1 inch of static pressure for the standard 3-1/4 x 10 inch vertical duct. Other duct choices shift them: the 7-inch round option takes the Glacier hoods to 250 CFM on high, and the Mantra’s low setting runs 1.1 to 1.3 sones across its duct options.
What a Kitchen Fan Has to Do
ASHRAE Standard 62.2 asks for one of two things in a kitchen: a range hood that vents outdoors and moves at least 100 CFM when you switch it on, or another kitchen exhaust fan, downdraft units included, moving 300 CFM. In an enclosed kitchen, one whose openings to other rooms total no more than 60 sq ft, that other fan may instead be sized to five air changes an hour of the kitchen’s volume, whether you switch it on or run it continuously; an open kitchen needs exhaust you switch on. The hood also has to be quiet enough to use: 62.2 requires a rating of 3 sones or less on at least one setting of 100 CFM or more.
Every ducted hood here clears 100 CFM on its lowest setting. The F403004’s lowest certified rating is 4.0 sones on the standard duct, so it fails. The Glacier and Mantra hoods pass with 1.5 and 1.3 sones on low. The exhaust fan size chart works through the five-air-changes rate for a given kitchen.
Certified CFM and Blower Rating
Listing titles often quote a hood’s maximum blower airflow, measured in open air with no duct. Broan marks that figure as not HVI-certified. The Glacier hoods are sold as 350 CFM, but their certified high setting is 240 CFM on the standard duct; the Mantra’s 490 CFM blower rating becomes 390 certified.
Makeup Air Above 400 CFM
Section M1503.6 of the 2021 International Residential Code requires makeup air for an exhaust system that can move more than 400 CFM, but only in a home with a fuel-burning appliance inside the air barrier that is neither direct-vent nor mechanically vented, such as a natural-draft gas water heater or furnace; whether a gas range counts, and which airflow rating applies, is a question for your building department. In that case the makeup air has to roughly equal the exhaust rate, through a damper that opens when the hood runs. Of the hoods here, only the Mantra is certified above 400 CFM, at 420 on the horizontal duct, and its open-air blower rating is 490.
Ducted vs Recirculating
A ducted hood sends cooking exhaust and steam outdoors. A recirculating hood passes the air through a grease filter and a charcoal filter and returns it to the kitchen, so the steam from cooking stays in the room; the EPA’s mold and moisture guide recommends venting stoves outside where possible to keep humidity down. A recirculating hood does not meet 62.2’s range hood requirement, which counts only a hood vented outdoors. Choose one only where a duct to the outside is impossible, as in many apartments; the Glacier and Mantra hoods convert to recirculating with an HPF30 filter kit, and the F403004 with a 41F filter.
Our Picks in Detail
Broan-NuTone Glacier GLA1303SS
Best for: A 30-inch electric or gas range in a kitchen that does everyday cooking, under a cabinet with a duct to the outside.
At 1.5 sones the low setting is quiet enough to leave on through a long simmer. High gives 240 CFM at 6.5 sones for searing or a pot at a rolling boil. It is ENERGY STAR certified, and both micro mesh filters go in the dishwasher.
It shares its certified airflow and sones with the three-speed GLA2303SS, and it costs less. You lose the middle speed, the delay-off setting and the GLA2’s two-level LED module; the GLA1 has a single-level LED bulb. Broan’s warranty is one year; its product page also lists three years on the LED.
Strengths
- Meets the 62.2 airflow and noise limits on low
- Same certified performance as the GLA2 for less
Limitations
- Two speeds only
- 240 CFM ceiling on the standard duct
Broan-NuTone Mantra MTR3304SS
Best for: Gas cooktops, frequent high-heat cooking and kitchens where the Glacier’s 240 CFM falls short.
Its certified high setting is 390 CFM on the standard vertical duct and 420 on a horizontal one, and under the harder 0.25 inch test it still holds 350 CFM on the vertical duct and 390 on the horizontal one. On low it runs 160 CFM at 1.1 to 1.3 sones, depending on the duct. A heat sensor raises the fan speed on its own when the cooktop gets hot.
On the standard vertical duct its 390 CFM stays under the 400 CFM makeup-air threshold. On a horizontal duct, or where your building department counts the 490 CFM blower rating, Broan’s installation guide shows how to set a limiter to 300 CFM, which gives up 120 CFM at the top on a horizontal duct and 90 on a vertical one. High runs 7.5 sones on the standard duct and 6.5 on a horizontal one. The hybrid baffle filters are dishwasher-safe.
Strengths
- Highest certified airflow of the five
- 1.3 sones on low
Limitations
- Highest Broan list price of the five
- 30-inch width only
Broan-NuTone 413004
Best for: A rental or condo kitchen with no duct to the outside and no permission to cut one.
It is built for recirculation only. Broan’s 41F combination grease and charcoal filter, the same part the F403004 takes for non-ducted use, catches grease and some odor. Broan says to replace it every six months, sooner with greasy cooking, and it cannot be washed.
Broan publishes no airflow figure for it and lists 3.5 sones without HVI certification, so none of its numbers line up with the ducted hoods in the table. Because nothing leaves the kitchen, open a window or run the bathroom fan while you cook, and see our apartment air quality guide for ventilating the rest of an apartment. The light takes an A19 LED bulb, not included.
Strengths
- Needs no duct to the outside
- Lowest Broan list price of the five
Limitations
- Steam and cooking exhaust stay in the kitchen
- No published airflow
Also Compared
The GLA2303SS adds the middle speed, delay-off setting and two-level LED module named in the GLA1 review; buy it if you want a setting between quiet and loud. The F403004 is the cheapest ducted hood here, and it tops out at 160 CFM on the standard duct as well as missing the noise limit.
Frequently Asked Questions
How many CFM does a range hood need?
At least 100 CFM for a hood vented outdoors. Above that, more airflow helps with high-heat cooking on gas; past 400 CFM, the makeup-air rule above can apply.
How long should I run the range hood?
For the whole time you cook. The EPA’s mold and moisture guide says to use exhaust fans or open windows whenever cooking or running the dishwasher. A hood with a delay-off setting, like the GLA2303SS, keeps running for a set time after you switch it off.
Is a downdraft vent as good as a hood?
Not by ASHRAE’s measure. ASHRAE 62.2 treats a downdraft unit as an “other” kitchen exhaust fan and asks it for 300 CFM, three times the 100 CFM it asks of a vented hood; only in an enclosed kitchen can five air changes an hour stand in for the 300. None of the picks here is a downdraft unit.
Can a range hood vent into the attic?
No. Section M1501.1 of the International Residential Code requires exhaust air to be discharged outdoors and bars exhausting it into an attic, soffit, ridge vent or crawl space. Run the duct to a roof or wall cap.